Prove a device behaves the way its profile says

A sandbox for integrators and equipment makers. Connect a device or a simulator, describe it with a profile, run bounded commands and get hashed compatibility evidence before the device touches a real grid.

  • Open with Wesfin ID
  • Beta
  • Physical devices not yet verified
  • No market settlement
This is what a compatibility report looks likeexample · profile DEMO-HB-2KW · not live data

PassPASSED

DEMO-HB-2KW@1.0.0 executes a bounded command and restores power after its lifetime

checks
12
commands
3
deviations
0
  • Simulator — present
  • Manifest hash — present
  • Physical device — absent
  • Market activation — absent
  1. SchemaPass
  2. SemanticPass
  3. SafetyPass
  4. ExecutionPass
  5. Physical benchNot run
  1. 01Device

    Connect a real device or a deterministic simulator.

    Simulator · MQTTHome Assistantstart: observe only

    canonical telemetry

  2. 02Profile

    Declare limits, signs and safety, no adapter code.

    profile_id@versionpower and SOC limitsttl_required

    immutable version

  3. 03Test

    Run deterministic tests and bounded commands.

    SCHEMA → SEMANTIC→ SAFETY → EXECUTIONPASS / FAIL / N/A apart

    compatibility report

  4. 04Evidence

    Get a hashed timeline anyone can re-verify.

    sha256requested != measuredSIMULATOR_ONLY

    JSON / Markdown export

Four ways to connect

Every source starts observe-only. Writes need separate local consent, fresh telemetry and bounded control switched on.

  • Simulator

    Available

    A deterministic BESS or load model. The same scenario and seed give the same evidence.

    seed · SimulatedClock
  • MQTT

    Available

    A local outbound connector, TLS broker and one-time credentials with scoped topics. Reconnect never replays commands.

    wesfin/lab/{workspace}/{asset}/telemetry
  • Home Assistant

    Available

    A declarative entity_id map with units and signs. Token and URL stay in your private file.

    ha-mapping · private token stays local
  • Modbus via Wesfin Edge

    Limited: reference fixture

    Reference register bank only for now, no physical devices.

    reference fixture

See it in a minute, no sign-in

An animation of a simulated water heater: how the Lab sends a bounded command and which evidence comes back. It is a teaching diagram, not live data.

How a bounded command travelsSIMULATED
  1. CommandThe Lab sends a power, a duration and a TTL within the profile's limits.
  2. AcknowledgedThe connector accepted the command.
  3. ExecutedThe device applied the new power.
  4. MeasuredAn independent measurement sees the change.
  5. RestoredAfter the duration the device returns to its baseline.

Each stage is separate evidence with its own source. An acknowledgement does not yet mean the power changed.

  • Equipment producers

    Describe your device with a profile, get a compatibility report and show it is ready for flexibility.

  • Integrators and installers

    Check MQTT or Home Assistant before a site visit, on the simulator and ready examples.

  • For your own home

    Learn how a water heater or battery can help the grid, and follow a guide step by step.

From the Lab to Wesfin Flex
  1. SimulatorYou build the profile and run tests without hardware.
  2. Validated profileEvery stage passed and there is a compatibility report.
  3. Physical benchWesfin tests a real device. A separate step.
  4. Wesfin FlexOnly after approval: taking part in flexibility.

The last two steps are outside the Lab and need separate approval by Wesfin. The Lab alone admits nothing to the market.

A bounded command has limits, a lifetime and evidence

Lab never mistakes an acknowledgement for a result. Each signal is recorded separately, and only an independent measurement confirms restoration.

  • ACK != EXECUTED != MEASUREDthree different proofs
  • ttl_required: truerestore after lifetime
  • replayed=falsereconnect never replays

format example · not live data

$ wesfin lab command send <asset_id> --power-kw 0.5 --duration 10s --ttl 15s✓ ACKNOWLEDGED   edge accepted the command✓ EXECUTED       register write confirmed by the device✓ MEASURED       independent meter reading✓ RESTORED       duration elapsed   replayed=false$ wesfin lab evidence get <command_id> --json
{  "authority": "SIMULATOR_ONLY",  "compatibility": "UNVERIFIED_REFERENCE",  "signals": {    "requested_kw": "…",    "commanded_kw": "…",    "feedback": "…",    "measured_kw": "…"  },  "market_settlement": null,  "manifest_sha256": "…"}

Honest status

  • Open sign-up

    Create a Wesfin ID account and your own sandbox. Wesfin staff sign in with their company account.

  • Beta

    Lab is still changing. A Lab compatibility report is not a device certification.

  • Physical devices unverified

    Evidence today is simulator or reference fixtures. PHYSICAL_UNVERIFIED

  • No market settlement

    Lab has no dispatch, market activation or settlement authority.

Start in Lab

Create a sandbox with a Wesfin ID account: email or phone and a second sign-in step. If you were invited to a workspace, sign in to see it.

A sandbox grants no right to control real equipment.